1 Hi guys, My heat pump decided to not run this morning. Got an E1 fault on the screen, which my manual says is High Gas Pressure Protection in the fault list. Anybody know what this means or what could be causing it? Heat pump is a Hayward HP65B (65,000 BTU) with vertical fan. Thanks Jeff Report ajw22 Gold Supporter TFP Guide Jul 21, 37,087
Learn Morethe power supply is suitable for use with a heat pump, and that it has a the test pressure on the low and high pressure sides must not exceed 42 bar.
Learn More5.4 Except there is water level error, hot water tank temp sensor error, when there is other temp error, high and low pressure error protection, electric heater
Learn MoreLock Heat Pump Heat Pump Inactive Press & Hold Power for 5 seconds Follow these steps to set the pool temperature. How To: Set Pool Temperature 10 Step 1 Step Verify the heater's power LED is illuminated, and put the heater is the desired mode. Using the up and down arrows adjust the heater to the desired temperature. 2
Learn MoreExamine Error Codes If you find that your power heater turns on but then keeps shutting off, this could indicate that you are having water pressure issues.
Learn MoreHigh pressure error. EE01. 1. Too much refrigerant,. 2. Too high water or environment temperature,. 3. Operating frequency is too high,. 4. Motor
Learn MoreThe water flow inside the heat pump is insufficient There is no water circulation inside the heat pump The flow switch is defective: Make sure the circulating pump works; Make sure the bypass valves are properly positioned; Check the skimmer (no obstruction); Check the water pressure gauge of the heat pump, it should read between 10 and 15 psi
Learn Morethe heat pump must be installed at a minimum distance from the end of the pool so High pressure fault. Insufficient water flow or faulty flow.
Learn MoreHP & HP6 - Low water flow in the unit or faulty high pressure control. Check water flow/backwash. The unit will show (HP6) after 6 HP faults. This will stop the unit for protection. FLo & FL3 - Possible causes: • The filter is in backwash position. • The filter pump is stopped. • The filter is dirty. • Shortage of water to pool pump.
Learn MoreIf your freon pressure is too low, it's an indicator that it's too cold outside for the heat pump to operate. After all, it needs at least some
Learn MoreStart the water pump before turning on the Machine to avoid any damage. - Press power on/off on LED controller to turn on/off machine. - During the first start of machine, please check if there is any water leakage in the piping connection system. Then set suitable temperature.